C0108 (bizhub 368/308)
Contents
Trouble type | C0108: Tray 4 paper feed motor turning at abnormal timing (When PC-210 is installed) |
Rank | B |
Trouble detection condition | • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | • Tray 4 paper feed motor (M121) • PC control board (PCCB) |
Procedure
- Check the connector between M121-PCCB CN9 for proper connection and correct as necessary.
- Check the connector of M121 for proper drive coupling and correct as necessary.
- M121 operation check
- Control signal: PCCB CN9-5 (CW/CCW)
- Location of electrical component: PC-210 6-K
- Replace M121. (Part# A2XMM10000)
- Replace PCCB. (Part# A2XMH00201)
NOTICE
- Link to the wiring diagram (PC-210)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.7.4 (Link to the Field Service Manual)