C0107 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C0107: Tray 3/transfer LCT vertical transport motor turning at abnormal timing (When PC-116, PC-216, or PC-416 is installed) | |
Rank | B | |
Trouble detection condition | •The control circuit detects motor failure to turn while the motor is turning. • The control circuit detects motor turning while the motor remains stationary. | |
Trouble isolation | – | |
Relevant electrical parts | <When PC-116 or PC-216 is installed> •Tray 3 vertical transport motor (M112) • PC control board (PCCB) <When PC-416 is installed> •Vertical transport motor (M132) • PC control board (PCCB) |
Procedure
When PC-116 or PC-216 is installed
- Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M112 for proper drive coupling and correct as necessary.
- M112 load check
- Check code: 28
- Multi code: 6, 9, 10
- Control signal: PCCB CN5-13 (CW/CCW)
- Location of electrical component: PC-116/PC-216 3 to 4-C
- Replace M112. (Part# A2XMM11000)
- Replace PCCB. (Part#AAV5H00101 / PC-216 Part# AAV5H00201)
When PC-416 is installed
- Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M132 for proper drive coupling and correct as necessary.
- M132 load check
- Check code: 28
- Multi code: 21, 24, 25
- Control signal: PCCB CN5-13 (CW/CCW)
- Location of electrical component: PC-416 4-J
- Replace M132. (Part# A2XMM11000)
- Replace PCCB. (Part# Part# AAV5H00300)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.6.3 (Link to the Field Service Manual)