C0107 (bizhub C368/C308/C258)

You are here:

Contents

Trouble typeC0107: Tray 3/transfer LCT vertical transport motor turning at abnormal timing (When PC-110, PC-210 or PC-410 is installed)
RankB
Trouble detection condition•The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
•The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-110 or PC-210 is installed>Tray 3 vertical transport motor (M112)PC control board (PCCB)

<When PC-410 is installed>Vertical transport motor (M132)PC control board (PCCB)

 Procedure

 When PC-110 or PC-210 is installed

  1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M112 for proper drive coupling and correct as necessary.
  3. M112 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-110/PC-210 3 to 4-C
  4. Replace M112. (Part#A2XMM10000)
  5. Replace PCCB. (PC-110 Part# A2XMH00101 / Part#A2XMH00201)

NOTICE

  • Link to the wiring diagram (PC-110)
  • Link to the wiring diagram (PC-210)

 When PC-410 is installed

  1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M132 for proper drive coupling and correct as necessary.
  3. M132 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-410 4-J
  4. Replace M132. (Part# A2XMM10000)
  5. Replace PCCB. (Part# A2XMH00301)

NOTICE

  • Link to the wiring diagram (PC-410)

Please review all part numbers for accuracy and current version.

K.3.7.2 (Field Service Manual Link)