C0106 (bizhub C368/C308/C258)
Contents
Trouble type | C0106: Tray 3/transfer LCT paper feed motor turning at abnormal timing (When PC-110, PC-210 or PC-410 is installed) | |
Rank | B | |
Trouble detection condition | •The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. •The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. | |
Trouble isolation | – | |
Relevant electrical parts | <When PC-110 or PC-210 is installed>Tray 3 paper feed motor (M111)PC control board (PCCB) | |
<When PC-410 is installed>Paper feed motor (M131)PC control board (PCCB) |
Procedure
When PC-110 or PC-210 is installed
- Check the connector between M111-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M111 for proper drive coupling and correct as necessary.
- M111 operation check
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-110/PC-210 4-C
- Replace M111 (Part#A2XMM10000)
- Replace PCCB. (PC-110 Part# A2XMH00101 / PC-210 Part#A2XMH00201)
Notice:
When PC-410 is installed
- Check the connector between M131-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M131 for proper drive coupling and correct as necessary.
- M131 operation check
- Control signal: PCCB CN5-5 (CW/CCW)
- Location of electrical component: PC-410 4-J
- Replace M131. (Part# A2XMM10000)
- Replace PCCB. (Part# A2XMH00301)
NOTICE:
- Link to the wiring diagram (PC-410)
Please verify all part numbers for accuracy and current version.