C0109 (bizhub C368/C308/C258)

You are here:

Contents

Trouble typeC0109: Tray 4 vertical transport motor turning at abnormal timing (When PC-210 is installed)
RankB
Trouble detection condition•The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
•The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical partsTray 4 vertical transport motor (M122)PC control board (PCCB)

 Procedure

  1. Check the connector between M122-PCCB CN9 for proper connection and correct as necessary.
  2. Check the connector of M122 for proper drive coupling and correct as necessary.
  3. M122 operation check
    • Control signal: PCCB CN9-13 (CW/CCW)
    • Location of electrical component: PC-210 6-K
  4. Replace M122. (Part# A2XMM10000)
  5. Replace PCCB. (Part# A2XMH00201)

NOTICE

  • Link to the wiring diagram (PC-210)

Please review all part numbers for accuracy and current version.