How Can We Help?

C0202 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC0202: Tray 1 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 1 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 1
Relevant electrical parts-Tray 1 lift-up motor (M12)
-Tray 1 upper limit sensor (PS22)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M12-MFPB CN7E for proper connection and correct as necessary.
  2. Check the connector of M12 for proper drive coupling and correct as necessary.
  3. Check the connector between PS22-relay CN48-MFPB CN10E for proper connection and correct as necessary.
  4. PS22 I/O check, sensor check
    • Control signal: MFPB CN10E-8 (ON)
    • Location of electrical component: 4-C
  5. M12 operation check
    • Control signal: MFPB CN7E-1 to 2
    • Location of electrical component: 7-C
  6. Replace M12. (Part# 9J06M10300)
  7. MFPB F5E conduction check
  8. Replace MFPB. (Part# A7AHH0201D)

NOTICE

K.3.7.6 (Link to the Field Service Manual)

Table of Contents