C0202 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0202: Tray 1 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 1 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 1 |
Relevant electrical parts | -Tray 1 lift-up motor (M12) -Tray 1 upper limit sensor (PS22) -MFP board (MFPB) |
Procedure
- Check the connector between M12-MFPB CN7E for proper connection and correct as necessary.
- Check the connector of M12 for proper drive coupling and correct as necessary.
- Check the connector between PS22-relay CN48-MFPB CN10E for proper connection and correct as necessary.
- PS22 I/O check, sensor check
- Control signal: MFPB CN10E-8 (ON)
- Location of electrical component: 4-C
- M12 operation check
- Control signal: MFPB CN7E-1 to 2
- Location of electrical component: 7-C
- Replace M12. (Part# 9J06M10300)
- MFPB F5E conduction check
- Replace MFPB. (Part# A7AHH0201D)
NOTICE
- Link to the wiring diagram (bizhub 367/287/227)