C0204 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0204: Tray 2 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 2 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 2 |
Relevant electrical parts | -Tray 2 lift-up motor (M13) -Tray 2 upper limit sensor (PS25) -MFP board (MFPB) |
Procedure
- Check the connector between M13-MFPB CN8E for proper connection and correct as necessary.
- Check the connector of M13 for proper drive coupling and correct as necessary.
- Check the connector between PS25-relay CN49-MFPB CN11E for proper connection and correct as necessary.
- PS25 I/O check, sensor check
- Control signal: MFPB CN11E-13 (ON)
- Location of electrical component: 6-C
- M13 operation check
- Control signal: MFPB CN8E-1 to 2
- Location of electrical component: 10-C
- Replace M13. (Part# 9J06M10300)
- MFPB F5E conduction check
- Replace MFPB. (Part# A7AHH0201D)
NOTICE
- Link to the wiring diagram (bizhub 367/287/227)
K.3.7.7 (Link to the Field Service Manual)