How Can We Help?

C0204 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC0204: Tray 2 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 2 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 2
Relevant electrical parts-Tray 2 lift-up motor (M13)
-Tray 2 upper limit sensor (PS25)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M13-MFPB CN8E for proper connection and correct as necessary.
  2. Check the connector of M13 for proper drive coupling and correct as necessary.
  3. Check the connector between PS25-relay CN49-MFPB CN11E for proper connection and correct as necessary.
  4. PS25 I/O check, sensor check
    • Control signal: MFPB CN11E-13 (ON)
    • Location of electrical component: 6-C
  5. M13 operation check
    • Control signal: MFPB CN8E-1 to 2
    • Location of electrical component: 10-C
  6. Replace M13. (Part# 9J06M10300)
  7. MFPB F5E conduction check
  8. Replace MFPB. (Part# A7AHH0201D)

NOTICE

K.3.7.7 (Link to the Field Service Manual)

Table of Contents