Trouble typeC0206: Tray 3 lift-up failure (When PC-113 or PC-213 is installed)
RankB
Trouble detection conditionThe tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts-Tray 3 lift-up motor (M113)
-Tray 3 upper limit sensor (PS116)
-PC control board (PCCB)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
  2. Check the connector of M113 for proper drive coupling and correct as necessary.
  3. Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
  4. PS116 I/O check, sensor check
    • Control signal: PCCB CN4-3 (ON)
    • Location of electrical component: PC-113/PC-213 7-C
  5. M113 operation check
    • Control signal: PCCB CN6-8 to 9
    • Location of electrical component: PC-113/PC-213 2-C
  6. Replace M113. (Part# 9J06M10300)
  7. Replace PCCB. (PC-113 Part# A7VAH00100 / PC-213 Part# A7VAH00200)
  8. MFPB F4E conduction check
  9. Replace MFPB. (Part# A7AHH0201D)