Trouble type | C0206: Tray 3 lift-up failure (When PC-113 or PC-213 is installed) |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | -Tray 3 lift-up motor (M113) -Tray 3 upper limit sensor (PS116) -PC control board (PCCB) -MFP board (MFPB) |
Procedure
- Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
- Check the connector of M113 for proper drive coupling and correct as necessary.
- Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
- PS116 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-113/PC-213 7-C
- M113 operation check
- Control signal: PCCB CN6-8 to 9
- Location of electrical component: PC-113/PC-213 2-C
- Replace M113. (Part# 9J06M10300)
- Replace PCCB. (PC-113 Part# A7VAH00100 / PC-213 Part# A7VAH00200)
- MFPB F4E conduction check
- Replace MFPB. (Part# A7AHH0201D)
NOTICE