C0208 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0208: Tray 4 lift-up failure (When PC-213 is installed) |
Rank | B |
Trouble detection condition | The tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 4 |
Relevant electrical parts | -Tray 4 lift-up motor (M123) -Tray 4 upper limit sensor (PS126) -PC control board (PCCB) -MFP board (MFPB) |
Procedure
- Check the connector between M123-PCCB CN8 for proper connection and correct as necessary.
- Check the connector of M123 for proper drive coupling and correct as necessary.
- Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary.
- PS126 I/O check, sensor check
- Control signal: PCCB CN7-3 (ON)
- Location of electrical component: PC-213 8-K
- M123 operation check
- Control signal: PCCB CN8-8 to 9
- Location of electrical component: PC-213 5-K
- Replace M123. (Part# 9J06M10300)
- Replace PCCB. (Part# A7VAH00200)
- MFPB F4E conduction check
- Replace MFPB. (Part# A7AHH0201D)
NOTICE
- Link to the wiring diagram (PC-213)
K.3.7.9 (Link to the Field Service Manual)