Trouble typeC0208: Tray 4 lift-up failure (When PC-213 is installed)
RankB
Trouble detection conditionThe tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 4
Relevant electrical parts-Tray 4 lift-up motor (M123)
-Tray 4 upper limit sensor (PS126)
-PC control board (PCCB)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M123-PCCB CN8 for proper connection and correct as necessary.
  2. Check the connector of M123 for proper drive coupling and correct as necessary.
  3. Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary.
  4. PS126 I/O check, sensor check
    • Control signal: PCCB CN7-3 (ON)
    • Location of electrical component: PC-213 8-K
  5. M123 operation check
    • Control signal: PCCB CN8-8 to 9
    • Location of electrical component: PC-213 5-K
  6. Replace M123. (Part# 9J06M10300)
  7. Replace PCCB. (Part# A7VAH00200)
  8. MFPB F4E conduction check
  9. Replace MFPB. (Part# A7AHH0201D)

NOTICE

  • Link to the wiring diagram (PC-213)

K.3.7.9 (Link to the Field Service Manual)