C0202 (bizhub 364e/284e/224e)
Contents
Trouble type | Tray 1 feeder up/down abnormality |
Trouble code | C0202 |
Rank | B |
Detection timing | The tray 1 upper limit sensor (PS25) is not blocked even after the lapse of a given period of time after the lifting motion has been started. |
Trouble isolation | Tray 1 |
Relevant electrical parts | • Tray 1 lift-up motor (M12) • Tray 1 upper limit sensor (PS25) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M12-PRCB CN25 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M12 for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS25-relay CN30-PRCB CN26 for proper connection and correct as necessary. | – | – |
4 | PS25 I/O check, sensor check | PRCB CN26-3 (ON) | 7-C |
5 | M12 operation check | PRCB CN25-5 (REM) | 1-C |
6 | Replace M12 (Part# 9J06M10300) | – | – |
7 | PRCB ICP5 conduction check | – | – |
8 | Replace PRCB (Part# A61FH00101) | – | – |
- Link to the wiring diagram (N.1. bizhub 364e/284e/224e)
- Link to the layout drawings for related parts by each trouble code (S.6. C0202)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.5.6 (Link to the Field Service Manual)