How Can We Help?

C0202 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeTray 1 feeder up/down abnormality
Trouble codeC0202
RankB
Detection timingThe tray 1 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Trouble isolationTray 1
Relevant electrical parts-Tray 1 lift-up motor (M12)
-Tray 1 upper limit sensor (PS22)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M12-PRCB CN25 for proper connection and correct as necessary.
2Check the connector of M12 for proper drive coupling and correct as necessary.
3Check the connector between PS25-relay CN30-PRCB CN26 for proper connection and correct as necessary.
4PS25 I/O check, sensor checkPRCB CN26-3 (ON)bizhub C364/C284 7-Cbizhub C224 10-C
5M12 operation checkPRCB CN25-5 (REM)1-C
6Replace M12 (Part# 9J06M10300)
7PRCB ICP5 conduction check
8Replace PRCB (Part# A161H00108)

K3.5.6 (Link to the Field Service Manual)