C0204 (bizhub C4050i/C3350i)
Contents
Trouble type | C0204: Tray 2 feeder up/down abnormality (When PF-P20 or PF-P21 is installed) |
Rank | B |
Trouble detection condition | The tray 2 upper limit sensor (PS2/2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 2 |
Relevant electrical parts | • Tray 2 lift-up motor (M2/2) • Tray 2 upper limit sensor (PS2/2) • Tray 2 PC control board (PCCB/2) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M2/2-PCCB/2 CN4 for proper connection and correct as necessary.
- Check the connector of M2/2 for proper drive coupling and correct as necessary.
- Check the connector between PS2/2-PCCB/2 CN3 for proper connection and correct as necessary.
- Check the connector between PCCB/2 CN1-relay CN24-BASEB CN21E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS2/2 I/O check, sensor check
- Control signal: PCCB/2 CN3-9 (ON)
- Location of electrical component: 18-X
- M2/2 load check
- Check code: 23
- Multi code: 5
- Control signal: PCCB/2 CN4-8 to 9
- Location of electrical component: 18-P
- Replace M2/2. (Part# 9J06M10300)
- Replace PCCB/2. (Part# AAJUH00100)
- Replace CPUB. (Part# A93EH01004)
- Replace BASEB. (Part# A93EH02007)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.6.4 (Link to the Field Service Manual)