C0206 (bizhub C4050i/C3350i)
Contents
Trouble type | C0206: Tray 3 feeder up/down abnormality (When PF-P20 or PF-P21 is installed) (bizhub C4050i only) |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS2/3) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | • Tray 3 lift-up motor (M2/3) • Tray 3 upper limit sensor (PS2/3) • Tray 3 PC control board (PCCB/3) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M2/3-PCCB/3 CN4 for proper connection and correct as necessary.
- Check the connector of M2/3 for proper drive coupling and correct as necessary.
- Check the connector between PS2/3-PCCB/3 CN3 for proper connection and correct as necessary.
- Check the connector between PCCB/3 CN1-relay CN2PC-PCCB/2 CN2 for proper connection and correct as necessary.
- Check the connector between PCCB/2 CN1-relay CN24-BASEB CN21E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS2/3 I/O check, sensor check
- Control signal: PCCB/3 CN3-9 (ON)
- Location of electrical component: 18-X
- M2/3 load check
- Check code: 23
- Multi code: 6
- Control signal: PCCB/3 CN4-8 to 9
- Location of electrical component: 18-P
- Replace M2/3. (Part# 9J06M10300)
- PCCB/3 F2 conduction check
- Replace PCCB/3. (Part# AAJUH00100)
- Replace CPUB. (Part# A93EH01004)
- Replace BASEB. (Part# A93EH02007)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.6.5 (Link to the Field Service Manual)