Trouble type Tray 3 lift-up failure
Trouble code C0206
Rank B
Detection timing The tray 3 upper limit sensor (PS116) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolation Tray 3
Relevant electrical parts • Tray 3 lift-up motor (M113)
• Tray 3 upper limit sensor (PS116)
• PC control board (PCCB)
• MFP board (MFPB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
2 Check the connector of M113 for proper drive coupling and correct as necessary.
3 Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
4 PS116 I/O check, sensor check PCCB CN4-3 (ON) PC-110/PC-210 7-C
5 M113 operation check PCCB CN6-8 to 9 PC-110/PC-210 2-C
6 Replace M113 (Part# 9J06M10300)
7 Replace PCCB (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201
8 Replace MFPB (Part# A61FH02005)