Trouble type Tray 4 lift-up failure
Trouble code C0208
Rank B
Detection timing The tray 4 upper limit sensor (PS126) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolation Tray 4
Relevant electrical parts • Tray 4 lift-up motor (M123)
• Tray 4 upper limit sensor (PS126)
• PC control board (PCCB)
• MFP board (MFPB)

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M123-PCCB CN8 for proper connection and correct as necessary.
2Check the connector of M123 for proper drive coupling and correct as necessary.
3Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary.
4PS126 I/O check, sensor checkPCCB CN7-3 (ON)PC-210 8-K
5M123 operation checkPCCB CN8-8 to 9PC-210 5-K
6Replace M123 (Part# 9J06M10300)
7Replace PCCB (part# Part# A2XMH00201)
8Replace MFPB (Part# A61FH02005)
  • Link to the wiring diagram (N.3.2 PC-210)
  • Link to the layout drawings for related parts by each trouble code (S.9. C0208)

Document Information ID D0001134243 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.5.9 (Link to the Field Service Manual)