Trouble typeC0206: Tray 3 feeder up/down abnormality (When PC-110 or PC-210 is installed)
RankB
Trouble detection conditionThe tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts• Tray 3 lift-up motor (M113)
• Tray 3 upper limit sensor (PS116)
• PC control board (PCCB)
• MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
  3. Check the connector of M113 for proper drive coupling and correct as necessary.
  4. Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
  5. PS116 I/O check, sensor check
    • Control signal: PCCB CN4-3 (ON)
    • Location of electrical component: PC-110/PC-210 7-C
  6. M113 operation check
    • Control signal: PCCB CN6-8 to 9
    • Location of electrical component: PC-110/PC-210 2-C
  7. Replace M113. (Part# 9J06M10300)
  8. Replace PCCB. (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)
  9. MFPB F1E conduction check
  10. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)