C0206 (bizhub 558/458)
Contents
Trouble type | C0206: Tray 3 feeder up/down abnormality (When PC-110 or PC-210 is installed) |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | • Tray 3 lift-up motor (M113) • Tray 3 upper limit sensor (PS116) • PC control board (PCCB) • MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
- Check the connector of M113 for proper drive coupling and correct as necessary.
- Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
- PS116 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-110/PC-210 7-C
- M113 operation check
- Control signal: PCCB CN6-8 to 9
- Location of electrical component: PC-110/PC-210 2-C
- Replace M113. (Part# 9J06M10300)
- Replace PCCB. (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)
- MFPB F1E conduction check
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
NOTICE
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.8.8 (Link to the Field Service Manual)