How Can We Help?

C0208 (bizhub 558/458)

You are here:

Contents

Trouble typeC0208: Tray 4 feeder up/down abnormality (When PC-210 is installed)
RankB
Trouble detection conditionThe tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 4
Relevant electrical parts• Tray 4 lift-up motor (M123)
• Tray 4 upper limit sensor (PS126)
• PC control board (PCCB)
• MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M123-PCCB CN8 for proper connection and correct as necessary.
  3. Check the connector of M123 for proper drive coupling and correct as necessary.
  4. Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary.
  5. PS126 I/O check, sensor check
    • Control signal: PCCB CN7-3 (ON)
    • Location of electrical component: PC-210 8-K
  6. M123 operation check
    • Control signal: PCCB CN8-8 to 9
    • Location of electrical component: PC-210 5-K
  7. Replace M123. (Part# 9J06M10300)
  8. Replace PCCB. (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)
  9. MFPB F1E conduction check
  10. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)

NOTICE

  • Link to the wiring diagram (PC-210)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.9 (Link to the Field Service Manual)

Table of Contents