C0210 (bizhub 558/458)
Contents
Trouble type | C0210: Transfer LCT lift failure (When PC-410 is installed) |
Rank | B |
Trouble detection condition | • The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operating. • The main tray upper limit sensor (PS136) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-down operation began. • The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-down operation began. |
Trouble isolation | LCT |
Relevant electrical parts | • Main tray upper limit sensor (PS136) • Shifter stop / lower limit position sensor (PS138) • Elevator motor (M134) • PC control board (PCCB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M134-PCCB CN10 for proper connection and correct as necessary.
- Check the connector of M134 for proper drive coupling and correct as necessary.
- Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary.
- Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary.
- PS136 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-410 8-J
- PS138 I/O check, sensor check
- Control signal: PCCB CN14-6 (ON)
- Location of electrical component: PC-410 3-J
- M134 operation check
- Control signal: PCCB CN10-1 to 2
- Location of electrical component: PC-410 6-J
- Replace M134. (Part# A2XMM10100)
- MFPB F1E conduction check
- Replace PCCB. (Part# A2XMH00301)
NOTICE
- Link to the wiring diagram (PC-410)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.8.10 (Link to the Field Service Manual)