Trouble typeC0206: Tray 3 feeder up/down abnormality (When PC-115 or PC-215 is installed)
RankB
Trouble detection conditionThe tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts• Tray 3 lift-up motor (M113)
• Tray 3 upper limit sensor (PS116)
• PC control board (PCCB)
• MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M113-PCCB CN6C for proper connection and correct as necessary.
  3. Check the connector of M113 for proper drive coupling and correct as necessary.
  4. Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
  5. PS116 I/O check, sensor check
    • Control signal: PCCB CN4-3 (ON)
    • Location of electrical component: PC-115/PC-215 7-C
  6. M113 load check
    • Check code: 23
    • Multi code: 6
    • Control signal: PCCB CN6C-8 to 9
    • Location of electrical component: PC-115/PC-215 2-C
  7. Replace M113. (Part# 9J06M10300)
  8. Replace PCCB. (Part# A2XMH00101)
  9. MFPB ICP1E conduction check (bizhub 368e/308e)
  10. MFPB F1E conduction check (bizhub 658e/558e/458e)
  11. Replace MFPB. (bizhub 368e/308e Part# AA6VH02101 / bizhub 658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.7.10 (Link to the Field Service Manual)