How Can We Help?
C0206 (bizhub 658e/558e/458e/368e/308e)
Contents
Trouble type | C0206: Tray 3 feeder up/down abnormality (When PC-115 or PC-215 is installed) |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | • Tray 3 lift-up motor (M113) • Tray 3 upper limit sensor (PS116) • PC control board (PCCB) • MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M113-PCCB CN6C for proper connection and correct as necessary.
- Check the connector of M113 for proper drive coupling and correct as necessary.
- Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
- PS116 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-115/PC-215 7-C
- M113 load check
- Check code: 23
- Multi code: 6
- Control signal: PCCB CN6C-8 to 9
- Location of electrical component: PC-115/PC-215 2-C
- Replace M113. (Part# 9J06M10300)
- Replace PCCB. (Part# A2XMH00101)
- MFPB ICP1E conduction check (bizhub 368e/308e)
- MFPB F1E conduction check (bizhub 658e/558e/458e)
- Replace MFPB. (bizhub 368e/308e Part# AA6VH02101 / bizhub 658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.7.10 (Link to the Field Service Manual)