C0206 (bizhub 958/808)

You are here:

Contents

Trouble typeC0206: Tray 3 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 3 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts• Tray 3 upper limit sensor (PS22)
• Tray 3 lift-up motor (M23)
• Paper feed/transport drive board (PFTDB)
• MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M23-PFTDB CN15 for proper connection and correct as necessary.
  3. Check the connector of M23 for proper drive coupling and correct as necessary.
  4. Check the connector between PS22-relay CN193-relay CN113B-PFTDB CN17 for proper connection and correct as necessary.
  5. PS22 I/O check, sensor check
    • Control signal: PFTDB CN17-6 (ON)
    • Location of electrical component: 6-X
  6. M23 operation check
    • Control signal: PFTDB CN15-3 to 4
    • Location of electrical component: 9-X
  7. Replace M23. (Part# A2X0M12101)
  8. PFTDB F12 conduction check
  9. Replace PFTDB. (Part# A796H00200)
  10. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.5 (Link to the Field Service Manual)