How Can We Help?

C0206 (bizhub 958/808)

You are here:

Contents

Trouble typeC0206: Tray 3 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 3 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts• Tray 3 upper limit sensor (PS22)
• Tray 3 lift-up motor (M23)
• Paper feed/transport drive board (PFTDB)
• MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M23-PFTDB CN15 for proper connection and correct as necessary.
  3. Check the connector of M23 for proper drive coupling and correct as necessary.
  4. Check the connector between PS22-relay CN193-relay CN113B-PFTDB CN17 for proper connection and correct as necessary.
  5. PS22 I/O check, sensor check
    • Control signal: PFTDB CN17-6 (ON)
    • Location of electrical component: 6-X
  6. M23 operation check
    • Control signal: PFTDB CN15-3 to 4
    • Location of electrical component: 9-X
  7. Replace M23. (Part# A2X0M12101)
  8. PFTDB F12 conduction check
  9. Replace PFTDB. (Part# A796H00200)
  10. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.5 (Link to the Field Service Manual)

Table of Contents