C0204 (bizhub 958/808)
Contents
Trouble type | C0204: Tray 2 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 2 upper limit sensor (PS14) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 2 |
Relevant electrical parts | Tray 2 upper limit sensor (PS14)Tray 2 lift-up motor (M8)Paper feed/transport drive board (PFTDB)MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M8-PFTDB CN24 for proper connection and correct as necessary.
- Check the connector of M8 for proper drive coupling and correct as necessary.
- Check the connector between PS14-relay CN155B-PFTDB CN12 for proper connection and correct as necessary.
- PS14 I/O check, sensor check
- Control signal: PFTDB CN12-17 (ON)
- Location of electrical component: 4-P
- M8 operation check
- Control signal: PFTDB CN24-10 to 11
- Location of electrical component: 4-X
- Replace M8. (Part# A2X0M12001)
- PFTDB F10 conduction check
- Replace PFTDB. (Part# A796H00200)
- Replace MFPB. (Part# A796H02003)
NOTICE
- Link to the wiring diagram (bizhub 958/808/758, bizhub PRO 958)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.4 (Link to the Field Service Manual)