C0206 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0206: Tray 3 lift-up failure (When PC-114 or PC-214 is installed) |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | -Tray 3 lift-up motor (M113) -Tray 3 upper limit sensor (PS116) -PC control board (PCCB) -MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M113-PCCB CN6C for proper connection and correct as necessary.
- Check the connector of M113 for proper drive coupling and correct as necessary.
- Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
- PS116 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-114/PC-214 7-C
- M113 operation check
- Control signal: PCCB CN6C-8 to 9
- Location of electrical component: PC-114/PC-214 2-C
- Replace M113. (Part# 9J06M10300)
- Replace PCCB. (PC-114 Part# A7VAH00100 / PC-214 Part# A7VAH00200)
- MFPB F11E conduction check
- Replace MFPB. (Part# A797H02118)
NOTICE
K.3.7.8 (Link to the Field Service Manual)