How Can We Help?

C0204 (bizhub C287/C227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC0204: Tray 2 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 2
Relevant electrical parts-Tray 2 lift-up motor (M13)
-Tray 2 upper limit sensor (PS22)
-MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M13-MFPB CN7E for proper connection and correct as necessary.
  3. Check the connector of M13 for proper drive coupling and correct as necessary.
  4. Check the connector between PS22-relay CN55-MFPB CN5E for proper connection and correct as necessary.
  5. PS22 I/O check, sensor check
    • Control signal: MFPB CN5E<B>-9 (ON)
    • Location of electrical component: 11-C
  6. M13 operation check
    • Control signal: MFPB CN7E<A>-13 to 14
    • Location of electrical component: 23-C
  7. Replace M13. (Part# 9J06M10300)
  8. MFPB F13E conduction check
  9. Replace MFPB. (Part# A797H02118)

NOTICE