C0204 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0204: Tray 2 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 2 |
Relevant electrical parts | -Tray 2 lift-up motor (M13) -Tray 2 upper limit sensor (PS22) -MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M13-MFPB CN7E for proper connection and correct as necessary.
- Check the connector of M13 for proper drive coupling and correct as necessary.
- Check the connector between PS22-relay CN55-MFPB CN5E for proper connection and correct as necessary.
- PS22 I/O check, sensor check
- Control signal: MFPB CN5E<B>-9 (ON)
- Location of electrical component: 11-C
- M13 operation check
- Control signal: MFPB CN7E<A>-13 to 14
- Location of electrical component: 23-C
- Replace M13. (Part# 9J06M10300)
- MFPB F13E conduction check
- Replace MFPB. (Part# A797H02118)
NOTICE
- Link to the wiring diagram (bizhub C287/C227)
K.3.7.7 (Link to the Field Service Manual)