C0208 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When PC-216 is installed
Contents
Trouble type | C0208: Tray 4 feeder up/down abnormality (When PC-216 is installed) |
Rank | B |
Trouble detection condition | The tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 4 |
Relevant electrical parts | -Tray 4 lift-up motor (M123) -Tray 4 upper limit sensor (PS126) -PC control board (PCCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M123-PCCB CN8C for proper connection and correct as necessary.
- Check the connector of M123 for proper drive coupling and correct as necessary.
- Check the connector between PS126-relay CN47-PCCB CN7C for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS126 I/O check, sensor check
- Control signal: PCCB CN7C-3 (ON)
- Location of electrical component: PC-216 8-K
- M123 load check
- Check code: 23
- Multi code: 7
- Control signal: PCCB CN8C-8 to 9
- Location of electrical component: PC-216 5-K
- Replace M123. (Part# 9J06M10300)
- Replace PCCB. (Part# AAV5H00201)
- Replace CPUB. (Part# AC77H02P02)
- Replace BASEB. (Part# AC77H02101)
When PC-417 is installed
Contents
Trouble type | C0208: Tray 4 feeder up/down abnormality (When PC-417 is installed) |
Rank | B |
Trouble detection condition | The tray 4 upper limit sensor (PS166) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 4 |
Relevant electrical parts | -Tray 4 lift-up motor (M144) -Tray 4 upper limit sensor (PS166 )-PC control board (PCCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M144-PCCB CN6 for proper connection and correct as necessary.
- Check the connector of M144 for proper drive coupling and correct as necessary.
- Check the connector between PS166-relay CN47-PCCB CN4 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS166 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-417 4-C
- M144 load check
- Check code: 23
- Multi code: 7
- Control signal: PCCB CN6-9 to 10
- Location of electrical component: PC-417 5-K
- Replace M144. (Part# A2X0M12101)
- PCCB PS301 conduction check
- Replace PCCB. (Part# AAV5H01401)
- Replace CPUB. (Part# AC77H02P02)