C0210 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0210: Transfer LCT lift failure (When PC-416 is installed) |
Rank | B |
Trouble detection condition | -The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the main tray began. -The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. -The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operating. -The main tray upper limit sensor (PS136) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-down operation began. -The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-down operation began. |
Trouble isolation | LCT |
Relevant electrical parts | -Main tray upper limit sensor (PS136) -Shifter stop / lower limit position sensor (PS138) -Elevator motor (M134) -PC control board (PCCB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M134-PCCB CN10L for proper connection and correct as necessary.
- Check the connector of M134 for proper drive coupling and correct as necessary.
- Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary.
- Check the connector between PS138-relay CN16-PCCB CN14L for proper connection and correct as necessary.
- PS136 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-416 8-J
- PS138 I/O check, sensor check
- Control signal: PCCB CN14L-6 (ON)
- Location of electrical component: PC-416 3-J
- M134 load check
- Check code: 23
- Multi code: 9, 10
- Control signal: PCCB CN10L-1 to 2
- Location of electrical component: PC-416 6-J
- Replace M134. (Part# A2XMM10100)
- Replace PCCB. (Part# AAV5H00300)