C0208 (bizhub 364e/284e/224e)
Contents
Trouble type | Tray 4 lift-up failure |
Trouble code | C0208 |
Rank | B |
Detection timing | The tray 4 upper limit sensor (PS126) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 4 |
Relevant electrical parts | • Tray 4 lift-up motor (M123) • Tray 4 upper limit sensor (PS126) • PC control board (PCCB) • MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M123-PCCB CN8 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M123 for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary. | – | – |
4 | PS126 I/O check, sensor check | PCCB CN7-3 (ON) | PC-210 8-K |
5 | M123 operation check | PCCB CN8-8 to 9 | PC-210 5-K |
6 | Replace M123 (Part# 9J06M10300) | – | – |
7 | Replace PCCB (Part# A2XMH00201) | – | – |
8 | Replace MFPB (Part# A61FH02005) | – | – |
- Link to the wiring diagram (N.2.4 PC-210)
- Link to the layout drawings for related parts by each trouble code (S.9. C0208)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.5.9 (Link to the Field Service Manual)