How Can We Help?

C0206 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeTray 3 lift-up failure
Trouble codeC0206
RankB
Detection timingThe tray 3 upper limit sensor (PS116) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts• Tray 3 lift-up motor (M113)
• Tray 3 upper limit sensor (PS116)
• PC control board (PCCB)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
2Check the connector of M113 for proper drive coupling and correct as necessary.
3Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
4PS116 I/O check, sensor checkPCCB CN4-3 (ON)PC-110/PC-210 7-C
5M113 operation checkPCCB CN6-8 to 9PC-110/PC-210 2-C
6Replace M113 (Part# 9J06M10300)
7Replace PCCB (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)
8Replace MFPB (Part# A61FH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.5.8 (Link to the Field Service Manual)

Table of Contents