How Can We Help?

C0208 (bizhub 754e/654e)

You are here:

Contents

Trouble typeTray 4 feeder up/down abnormality
Trouble codeC0208
RankB
Detection timingThe tray 4 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Trouble isolationTray 4
Relevant electrical parts• Tray 4 upper limit sensor (PS27)
• Tray 4 lift-up motor (M24)
• Paper feed/transport drive board (PFTDB)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M24-PFTDB CN18 for proper connection and correct as necessary.
2Check the connector of M24 for proper drive coupling and correct as necessary.
3Check the connector between PS27-relay CN194-relay CN121B-PFTDB CN22 for proper connection and correct as necessary.
4PS27 I/O check, sensor checkPFTDB CN22-6 (ON)8-X
5M24 operation checkPFTDB CN18-1 to 29-X
6Replace M24 (Part# A2X0M12101 )
7PFTDB ICP8 conduction check
8Replace PFTDB (Part# A2X0H00202 )
9Replace PRCB (Part# A55VH00105 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.5.6

Table of Contents