How Can We Help?

C0206 (bizhub 754e/654e)

You are here:

Contents

Trouble typeTray 3 feeder up/down abnormality
Trouble codeC0206
RankB
Detection timingThe tray 3 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Trouble isolationTray 3
Relevant electrical parts• Tray 3 upper limit sensor (PS22)
• Tray 3 lift-up motor (M23)
• Paper feed/transport drive board (PFTDB)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M23-PFTDB CN18 for proper connection, and correct as necessary.
2Check the connector of M23 for proper drive coupling and correct as necessary.
3Check the connectors between PS22-relay CN193-relay CN113B-PFTDB CN20 for proper connection, and correct as necessary.
4PS22 I/O check, sensor checkPFTDB CN20-6 (ON)6-X
5M23 operation checkPFTDB CN18-3 to 49-X
6Replace M23 (Part# A2X0M12101 )
7PFTDB ICP7 conduction check
8Replace PFTDB (Part# A2X0H00202 )
9Replace PRCB (Part# A55VH00105 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.5.5