C0208 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC0208: Tray 4 feeder up/down abnormality (When PC-216 is installed)
RankB
Trouble detection conditionThe tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 4
Relevant electrical parts•Tray 4 lift-up motor (M123)
• Tray 4 upper limit sensor (PS126)
• PC control board (PCCB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M123-PCCB CN8C for proper connection and correct as necessary.
  3. Check the connector of M123 for proper drive coupling and correct as necessary.
  4. Check the connector between PS126-relay CN47-PCCB CN7C for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. PS126 I/O check, sensor check
    • Control signal: PCCB CN7C-3 (ON)
    • Location of electrical component: PC-216 8-K
  7. M123 load check
    • Check code: 23
    • Multi code: 7
    • Control signal: PCCB CN8C-8 to 9
    • Location of electrical component: PC-216 5-K
  8. Replace M123. (Part# 9J06M10300)
  9. Replace PCCB. (Part# AAV5H00201)
  10. Replace CPUB. (Part# AA2JH02N06)
  11. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.6.9 (Link to the Field Service Manual)