C0206 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC0206: Tray 3 feeder up/down abnormality (When PC-116 or PC-216 is installed)
RankB
Trouble detection conditionThe tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts•Tray 3 lift-up motor (M113)
• Tray 3 upper limit sensor (PS116)
• PC control board (PCCB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M113-PCCB CN6C for proper connection and correct as necessary.
  3. Check the connector of M113 for proper drive coupling and correct as necessary.
  4. Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. PS116 I/O check, sensor check
    • Control signal: PCCB CN4-3 (ON)
    • Location of electrical component: PC-116/PC-216 7-C
  7. M113 load check
    • Check code: 23
    • Multi code: 6
    • Control signal: PCCB CN6C-8 to 9
    • Location of electrical component: PC-116/PC-216 2-C
  8. Replace M113. (Part# 9J06M10300)
  9. Replace PCCB. (Part#AAV5H00101 / PC-216 Part# AAV5H00201)
  10. Replace CPUB. (Part# AA2JH02N06)
  11. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.6.8 (Link to the Field Service Manual)