How Can We Help?

C0204 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC0204: Tray 2 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 2
Relevant electrical parts•Tray 2 lift-up motor (M13)
• Tray 2 upper limit sensor (PS22)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M13-relay CN181-BASEB CN25E for proper connection and correct as necessary.
  3. Check the connector of M13 for proper drive coupling and correct as necessary.
  4. Check the connector between PS22-relay CN40-BASEB CN23E for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. PS22 I/O check, sensor check
    • Control signal: BASEB CN23E-12 (ON)
    • Location of electrical component: 16-K
  7. M13 load check
    • Check code: 23
    • Multi code: 5
    • Control signal: BASEB CN25E-10 (REM)
    • Location of electrical component: 18-K
  8. Replace M13. (Part# 9J06M10300)
  9. Replace CPUB. (Part# AA2JH02N06)
  10. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.6.7 (Link to the Field Service Manual)

Table of Contents