Trouble typeTray 4 lift-up failure
Trouble codeC0208
RankB
Detection timingThe tray 4 upper limit sensor (PS126) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolation-Tray 4
Relevant electrical parts-Tray 4 lift-up motor (M123)
-Tray 4 upper limit sensor (PS126)
-PC control board (PCCB)
-MFP board (MFPB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M123-PCCB CN8 for proper connection and correct as necessary.
2Check the connector of M123 for proper drive coupling and correct as necessary.
3Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary.
4PS126 I/O check, sensor checkPCCB CN7-3 (ON)PC-210 8-K
5M123 operation checkPCCB CN8-8 to 9PC-210 5-K
6Replace M123 (Part# 9J06M10300)
7Replace PCCB (Part# A2XMH00201)
8Replace MFPB (C364/C284 Part# A161H02104 / C224 Part# A4FMH02208)
  • Link to the wiring diagram (N.2.4 PC-210)
  • Link to the layout drawings for related parts by each trouble code (S.9. C0208)

K3.5.9 (Link to the Field Service Manual)