Trouble typeTray 3 lift-up failure
Trouble codeC0206
RankB
Detection timingThe tray 3 upper limit sensor (PS116) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts-Tray 3 lift-up motor (M113)
-Tray 3 upper limit sensor (PS116)
-PC control board (PCCB)
-MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
2Check the connector of M113 for proper drive coupling and correct as necessary.
3Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
4PS116 I/O check, sensor checkPCCB CN4-3 (ON)PC-110/PC-210 7-C
5M113 operation checkPCCB CN6-8 to 9PC-110/PC-210 2-C
6Replace M113 (Part# 9J06M10300)
7Replace PCCB (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)
8Replace MFPB (C364/C284 Part# A161H02104 / C224 Part# A4FMH02208)