C0208 (bizhub C658/C558/C458)
Contents
Trouble type | C0208: Tray 4 feeder up/down abnormality (When PC-215 is installed) |
Rank | B |
Trouble detection condition | The tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 4 |
Relevant electrical parts | •Tray 4 lift-up motor (M123) •Tray 4 upper limit sensor (PS126) •PC control board (PCCB) •MFP board (MFPB) |
Procedure
- Remove thetray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M123-PCCB CN8C for proper connection and correct as necessary.
- Check the connector of M123 for proper drive coupling and correct as necessary.
- Check the connector between PS126-relay CN47-PCCB CN7C for proper connection and correct as necessary.
- PS126 I/O check, sensor check
- Control signal: PCCB CN7C-3 (ON)
- Location of electrical component: PC-215 8-K
- M123 operation check
- Control signal: PCCB CN8C-8 to 9
- Location of electrical component: PC-215 5-K
- Replace M123. (Part# 9J06M10300)
- Replace PCCB. (Part# A2XMM11000)
- MFPB F1E conduction check
- Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Item # 9 Part # A79JH02102)
NOTICE
- Link to the wiring diagram (PC-215)
Please review all parts for accuracy and current version.
K.3.8.9 (Link to the Field Service Manual)