C0208 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0208: Tray 4 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 4 upper limit sensor (PS27) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 4 |
Relevant electrical parts | -Tray 4 upper limit sensor (PS27) -Tray 4 lift-up motor (M24) -Paper feed/transport drive board (PFTDB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M24-PFTDB CN15 for proper connection and correct as necessary.
- Check the connector of M24 for proper drive coupling and correct as necessary.
- Check the connector between PS27-relay CN194-relay CN121B-PFTDB CN19 for proper connection and correct as necessary.
- PS27 I/O check, sensor check
- Control signal: PFTDB CN19-6 (ON)
- Location of electrical component: 8-X
- M24 load check
- Check code: 23
- Multi code: 7
- Control signal: PFTDB CN15-1 to 2
- Location of electrical component: 9-X
- Replace M24. (Part# A2X0M12101)
- PFTDB F12 conduction check
- Replace PFTDB. (Part# A795H00200)
L.3.7.6 (Link to the Field Service Manual)