How Can We Help?

C0210 (bizhub 658e/558e/458e/368e/308e)

You are here:

Contents

Trouble typeC0210: Transfer LCT lift failure (When PC-415 is installed)
RankB
Trouble detection condition• The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
• The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
• The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operating.
• The main tray upper limit sensor (PS136) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-down operation began.
• The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-down operation began.
Trouble isolationLCT
Relevant electrical parts• Main tray upper limit sensor (PS136)
• Shifter stop / lower limit position sensor (PS138)
• Elevator motor (M134)
• PC control board (PCCB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M134-PCCB CN10L for proper connection and correct as necessary.
  3. Check the connector of M134 for proper drive coupling and correct as necessary.
  4. Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary.
  5. Check the connector between PS138-relay CN16-PCCB CN14L for proper connection and correct as necessary.
  6. PS136 I/O check, sensor check
    • Control signal: PCCB CN4-3 (ON)
    • Location of electrical component: PC-415 8-J
  7. PS138 I/O check, sensor check
    • Control signal: PCCB CN14L-6 (ON)
    • Location of electrical component: PC-415 3-J
  8. M134 load check
    • Check code: 23
    • Multi code: 9, 10
    • Control signal: PCCB CN10L-1 to 2
    • Location of electrical component: PC-415 6-J
  9. Replace M134. (Part# A2XMM10100)
  10. MFPB ICP1E conduction check (bizhub 368e/308e)
  11. MFPB F1E conduction check (bizhub 658e/558e/458e)
  12. Replace PCCB. (Part# A2XMH00301)