C0210 (bizhub C554e/C454e)
(1)Contents
Trouble type | LCT lift failure |
Trouble code | C0210 |
Rank | B |
Detection timing | • The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operating. • The main tray upper limit sensor (PS136) is not unblocked even after the set period of time has elapsed after the paper lift-down operation began. • The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the paper lift-down operation began. |
Trouble isolation | LCT |
Relevant electrical parts | • Main tray upper limit sensor (PS136) • Shifter stop / lower limit position sensor (PS138) • Elevator motor (M134) • PC control board (PCCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M134-PCCB CN10 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M134 for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary. | – | – |
4 | Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary. | – | – |
5 | PS136 I/O check, sensor check | PCCB CN4-3 (ON) | PC-410 8-J |
6 | PS138 I/O check, sensor check | PCCB CN14-6 (ON) | PC-410 4-J |
7 | M134 operation check | PCCB CN10-1 to 2 | PC-410 6-J |
8 | Replace M134 (Part# (A2XMM10100) | – | – |
9 | PCCB IC2 conduction check | – | – |
10 | Replace PCCB (Part#( A2XMH00301) | – | – |
- Link to the wiring diagram (N.3.3 PC-410)
- Link to the layout drawings for related parts by each trouble code (S.10. C0210)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.5.10 (Link to the Field Service Manual)