How Can We Help?
C0211 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0211: Manual feed up/down abnormality |
Rank | B |
Trouble detection condition | -The bypass lift-up position sensor (PS26) is not turned OFF (unblock) even after the paper feed motor (M22) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. -The bypass lift-up position sensor (PS26) is not turned ON (blocked) even after the paper feed motor (M22) rotates for a given period of time after the position is switched from feed position at lift-up plate to the stand by position. |
Trouble isolation | Manual |
Relevant electrical parts | -Paper feed motor (M22) -Bypass tray lift-up solenoid (SD1) -Bypass tray lift-up position sensor (PS26) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between M22-BASEB CN31E for proper connection and correct as necessary.
- Check the connector of M22 for proper drive coupling and correct as necessary.
- Check the connector between PS26-relay CN13-BASEB CN26E for proper connection and correct as necessary.
- Check the connector between SD1-relay CN21-relay CN13-BASEB CN26E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS26 I/O check, sensor check
- Control signal: BASEB CN26EA-6 (ON)
- Location of electrical component: 9-K
- SD1 load check
- Check code: 23
- Multi code: 3
- Control signal: BASEB CN26EA-9 (ON)
- Location of electrical component: 10-K
- M22 load check
- Check code: 28
- Multi code: 31, 34, 35
- Control signal: BASEB CN31E-1 to 4
- Location of electrical component: 23-K
- Replace M22. (Part# ACKNM10000)
- Replace CPUB. (Part# ACKNH02P03)
- Replace BASEB. (Part# ACKNH02101)