How Can We Help?
C0216 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0216: External LCT up/down abnormality (When LU-205 or LU-303 is installed) |
Rank | B |
Trouble detection condition | The LU upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | LCT |
Relevant electrical parts | -LU upper limit sensor (PS2) -LU lift-up motor (M1) -LU drive board (LUDB) |
Procedure
- Check the connector between M1-LUDB CN3 for proper connection and correct as necessary.
- Check the connector of M1 for proper drive coupling and correct as necessary.
- Check the connector between PS2-relay CN406-LUDB CN5 for proper connection and correct as necessary.
- PS2 I/O check, sensor check
- Control signal: LUDB CN5-3 (ON)
- Location of electrical component: LU-205/LU-303 4-G
- M1 load check
- Check code: 23
- Multi code: 8
- Control signal: LUDB CN3-4 (ON)
- Location of electrical component: LU-205/LU-303 3-G
- Replace M1. (LU-205 / LU-303) (Part# A00JR74900)
- Replace LUDB. (LU-205 (Part# A8H6H00100)/ LU-303 (Part# A8H6H00100))