C0216 (bizhub C554e/C454e)

You are here:

(1)Contents

Trouble typeLCT up/down abnormality
Trouble codeC0216
RankB
Detection timingThe upper limit sensor (PS2) is not blocked even after the set period of time has elapsed after the paper lift-up operation began.
Trouble isolationLCT
Relevant electrical parts• Upper limit sensor (PS2)
• Lift-up motor (M1)
• LU drive board (LUDB)

 (2)ProcedureWhen LU-204 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M1-LCDB CN3 for proper connection, and correct as necessary.
2Check the connector of M1 for proper drive coupling and correct as necessary.
3Check the connectors between PS2-relay CN406-LCDB CN5 for proper connection, and correct as necessary.
4PS2 I/O check, sensor checkLUDB CN5-3 (ON)LU-204 4-G
5M1 operation checkLUDB CN3-4 (ON)LU-204 3-G
6Replace M1 (Part# A00JR74900)
7LUDB ICP2 conduction check
8Replace LUDB (Part# A0TJH00100)
  • Link to the wiring diagram (N.3.4 LU-204)
  • Link to the layout drawings for related parts by each trouble code (S.13. C0216)

When LU-301 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M1-LCDB CN3 for proper connection, and correct as necessary.
2Check the connector of M1 for proper drive coupling and correct as necessary.
3Check the connectors between PS2-relay CN3-LCDB CN5 for proper connection, and correct as necessary.
4PS2 I/O check, sensor checkLUDB CN5-3 (ON)LU-301 4-G
5M1 operation checkLUDB CN3-4 (ON)LU-301 3-G
6Replace M1 (Part# A00JR74900)
7LUDB ICP2 conduction check
8Replace LUDB (Part# A0TJH00100)
  • Link to the wiring diagram (N.3.5 LU-301)