C0214 (bizhub C554e/C454e)

You are here:

(1)Contents

Trouble typeLCT shift failure
Trouble codeC0214
RankB
Detection timing• The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right).
• The shifter home sensor (PS139) is not unblocked even after the set period of time has elapsed after the shift operation began (shift to the right).
• The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the return operation began (shift to the left).
• The shifter home sensor (PS139) is not blocked even after the set period of time has elapsed after the return operation began (shift to the left).
Trouble isolationLCT
Relevant electrical parts• Shifter motor (M133)
• Shifter stop / lower limit position sensor (PS138)
• Shifter home sensor (PS139)
• PC control board (PCCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M133-PCCB CN10 for proper connection and correct as necessary.
2Check the connector of M133 for proper drive coupling and correct as necessary.
3Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary.
4Check the connector between PS139-relay CN16-PCCB CN14for proper connection and correct as necessary.
5PS138 I/O check, sensor checkPCCB CN14-6 (ON)PC-410 4-J
6PS139 I/O check, sensor checkPCCB CN14-3 (ON)PC-410 4-J
7M133 operation checkPCCB CN10-3 to 4PC-410 6-J
8Replace M133 (Part# A2XMM10100)
9PCCB IC2 conduction check
10Replace PCCB (Part# A2XMH00301)
  • Link to the wiring diagram (N.3.3 PC-410)
  • Link to the layout drawings for related parts by each trouble code (S.12. C0214)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.5.12 (Link to the Field Service Manual)