How Can We Help?

C1102 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeMain tray up/down motors drive malfunction
Trouble codeC1102
RankB
Detection timing<When FS-533 is installed>
-While the exit tray is being lifted, the stapler movement motor (M107) is not unblocked after the set period of time has elapsed after the tray lift up motor (M109) is turned ON.
-While the exit tray is being lowered, the stapler movement motor (M107) is not blocked after the set period of time has elapsed after the tray lift up motor (M109) is turned ON
<When FS-534 is installed>
-While the exit tray is being lifted, the main tray upper position sensor (PS26/PS27) is not blocked and the main tray upper position detect switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by the set number of times.
-While the exit tray is being lowered, the main tray full detection sensor (PS29) is not blocked after the set period of time has elapsed after the main tray up/down motor (M11) is turned ON.
Trouble isolation
Relevant electrical parts<When FS-533 is installed>
-Tray lift up motor (M109)
-Stapler movement motor (M107)
-FS control board (FSCB)
<When FS-534 is installed>
-Main tray up/down motor (M11)
-Main tray upper position sensor/R (PS26)
-Main tray upper position sensor/F (PS27)
-Main tray full detection sensor (PS29)
-Main tray upper position detect switch (SW2)
-FS control board (FSCB)

(2)Procedure When FS-533 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M109-FSCB CN108 for proper connection and correct as necessary.
2Check the connector of M109 for proper drive coupling and correct as necessary.
3Check the connector between PS107-FSCB CN110 for proper connection and correct as necessary.
4PS107 I/O check, sensor checkFSCB CN110FS-533 7-D to E
5M109 operation checkFSCB CN108FS-533 10-E
6Replace M109 (Part# A2YUPPW300)
7FSCB CP109 conduction check
8Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

When FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the motor and sensor connectors for proper connection, and correct as necessary.
2Check the connector of M11 for proper drive coupling, and correct as necessary.
3PS26 I/O check, sensor checkFSCB J14<A>-5 (ON)FS-534 2-C
4PS27 I/O check, sensor checkFSCB J14<B>-8 (ON)FS-534 3-C
5PS29 I/O check, sensor checkFSCB J14<A>-8 (ON)FS-534 4-C
6SW2 operation checkFSCB J10-1~2FS-534 8-K
7M11 operation checkFSCB J9<A>-9 to 10FS-534 10-C to D
8Replace M11 (Part# A3EPPPA703)
9Replace FSCB (Part# A3EPPPBE01)

K3.6.3 (Link to the Field Service Manual)