How Can We Help?

C1103 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeAlignment plate motor/Frs malfunction
Trouble codeC1103
RankB
Detection timing<When FS-533 is installed>
-The alignment plate home sensor/F (PS108) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position.
-The alignment plate home sensor/F (PS108) is not blocked after the set period of time has elapsed after the alignment motor/F (M105) is turned ON to return the plate to the home position.
<When FS-534 is installed>
-The alignment plate/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position.
-The alignment plate/F home sensor (PS12) is not blocked after the set period of time has elapsed after the alignment motor/front (M7) is turned ON to return the plate to the home position.
-The alignment plate/F does not reach the specified position within the set period of time.
Trouble isolation
Relevant electrical parts<When FS-533 is installed>
-Alignment motor/F (M105)
-Alignment plate home sensor/F (PS108)
-FS control board (FSCB)
<When FS-534 is installed>
-Alignment motor/Front (M7)
-Alignment plate/F home sensor (PS12)
-FS control board (FSCB)

(2)Procedure When FS-533 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M105-FSCB CN102 for proper connection and correct as necessary.
2Check the connector of M105 for proper drive coupling and correct as necessary.
3Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary.
4PS108 I/O check, sensor checkFSCB CN102FS-533 7-J
5M105 operation checkFSCB CN102FS-533 7-J
6Replace M105 (Part# A2YUPPW600)
7FSCB CP105 conduction check
8Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

When FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M7-FSCB J4 for proper connection and correct as necessary.
2Check the connector of M7 for proper drive coupling, and correct as necessary.
3Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.
4PS12 I/O check, sensor checkFSCB J4<B>-4 (ON)FS-534 13-C
5M7 operation checkFSCB J4<A>-5 to 8FS-534 11-C to D
6Replace M7 (Part# A3EPPP5500)
7Replace FSCB (Part# A3EPPPBE01)

K3.6.4 (Link to the Field Service Manual)

Table of Contents