Trouble typeBundle eject motors drive malfunction
Trouble codeC1105
RankB
Detection timing<When FS-534 is installed>
-The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the gripper position detection sensor (PS19) unblocked.
-The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after it unblock
-The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after the gripper home position sensor (PS18) unblocked.
-The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the bundle eject motor (M10) unblocked.The gripper home position sensor (PS18) and the gripper position detection sensor (PS19) are blocked at the same time.
Trouble isolation
Relevant electrical parts-Bundle eject motor (M10)
-Gripper home position sensor (PS18)
-Gripper position detection sensor (PS19)
-FS control board (FSCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the motor and sensor connectors for proper connection, and correct as necessary.
2Check the connector of M10 for proper drive coupling, and correct as necessary.
3PS18 I/O check, sensor checkFSCB J13-13 (ON)FS-534 7-C
4PS19 I/O check, sensor checkFSCB J12-3 (ON)FS-534 7-C
5M10 operation checkFSCB J13-1 to 2FS-534 8-C to D
6Replace M10 (Part# A87GPP1400)
7Replace FSCB (Part# A3EPPPBE01)
  • Link to the wiring diagram (N.2.7 FS-534)