C1103 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC1103: Alignment motor/Fr drive malfunction
RankB
Trouble detection condition<When FS-533 is installed>
•The alignment plate/Fr home sensor (PS108) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.
• The alignment plate home sensor/Fr (PS108) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Fr (M105) is turned ON to return the plate to the home position.

<When FS-536 or FS-536SD is installed>
•The alignment plate/Fr home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.
• The alignment plate/Fr home sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Fr (M7) is turned ON to return the plate to the home position.
• The alignment plate/F does not reach the specified position within the set period of time.
Trouble isolation
Relevant electrical parts<When FS-533 is installed>
•Alignment motor/Fr (M105)
• Alignment plate/Fr home sensor (PS108)
• FS control board (FSCB)

<When FS-536 or FS-536SD is installed>
•Alignment motor/Fr (M7)
• Alignment plate/Fr home sensor (PS12)
• FS control board (FSCB)

Procedure

When FS-533 is installed

  1. Check the connector between M105-FSCB CN102 for proper connection and correct as necessary.
  2. Check the connector of M105 for proper drive coupling and correct as necessary.
  3. Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary.
  4. PS108 I/O check, sensor check
    • Control signal: FSCB CN102
    • Location of electrical component: FS-533 7-J
  5. M105 operation check
    • Control signal: FSCB CN102
    • Location of electrical component: FS-533 7-J
  6. Replace M105. (Part# A2YUPPW600)
  7. FSCB CP105 conduction check
  8. Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

When FS-536 or FS-536SD is installed

  1. Check the connector between M7-FSCB J4 for proper connection and correct as necessary.
  2. Check the connector of M7 for proper drive coupling and correct as necessary.
  3. Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.
  4. PS12 I/O check, sensor check
    • Control signal: FSCB J4<B>-4 (ON)
    • Location of electrical component: FS-536/FS-536SD 15-C
  5. M7 operation check
    • Control signal: FSCB J4<A>-5 to 8
    • Location of electrical component: FS-536/FS-536SD 14-C
  6. Replace M7. (Part# A3EPPP5500)
  7. Replace FSCB. (Part# A87GPP0V00)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.7.4 (Link to the Field Service Manual)