C1103 (bizhub C364e/C284e/C224e)
Contents
Trouble type | Alignment plate motor/Fr’s malfunction | |
Trouble code | C1103 | |
Rank | B | |
Detection timing | <When FS-533 is installed> • The alignment plate home sensor/F (PS108) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate home sensor/F (PS108) is not blocked after the set period of time has elapsed after the alignment motor/F (M105) is turned ON to return the plate to the home position. | |
<When FS-534 is installed> • The alignment plate/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate/F home sensor (PS12) is not blocked after the set period of time has elapsed after the alignment motor/front (M7) is turned ON to return the plate to the home position. • The alignment plate/F does not reach the specified position within the set period of time. | ||
Trouble isolation | – | |
Relevant electrical parts | <When FS-533 is installed> • Alignment motor/F (M105) • Alignment plate home sensor/F (PS108) • FS control board (FSCB) | |
<When FS-534 is installed> • Alignment motor/Front (M7) • Alignment plate/F home sensor (PS12) • FS control board (FSCB) |
(2)ProcedureWhen FS-533 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M105-FSCB CN102 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M105 for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary. | – | – |
4 | PS108 I/O check, sensor check | FSCB CN102 | FS-533 7-J |
5 | M105 operation check | FSCB CN102 | FS-533 7-J |
6 | Replace M105 (Part# A2YUPPW600) | – | – |
7 | FSCB CP105 conduction check | – | – |
8 | Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2)) | – | – |
- Link to the wiring diagram (N.2.6 FS-533)
- Link to the layout drawings for related parts by each trouble code (S.16.1 FS-533)
When FS-534 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M7-FSCB J4 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M7 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS12-FSCB J4 for proper connection and correct as necessary. | – | – |
4 | PS12 I/O check, sensor check | FSCB J4<B>-4 (ON) | FS-534 13-C |
5 | M7 operation check | FSCB J4<A>-5 to 8 | FS-534 11-C to D |
6 | Replace M7 (Part# A3EPPP5500) | – | – |
7 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.7 FS-534)
- Link to the layout drawings for related parts by each trouble code (S.16.2 FS-534)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.4 (Link to the Field Service Manual)