How Can We Help?

C1106 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC1106: Stapler movement motor malfunction (When FS-533, FS-534 or FS-534SD is installed)
RankB
Trouble detection condition<When FS-533 is installed>
-The stapler home sensor (PS110) is not turned OFF (unblocked) after the laps of given time after it started operating from the home position.
-The stapler home sensor (PS110) is not turned ON (blocked) after the laps of give time after the stapler movement motor (M107) turned ON when it returned to the home position.
<When FS-534 or FS-534SD is installed>
-The stapler home position sensor (Rear) (PS23) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON.
-The stapler does not reach the specified position within the set period of time.
Trouble isolationStaple
Relevant electrical parts<When FS-533 is installed>Stapler movement motor (M107)
-Stapler home sensor (PS110)
-Stapler relay board (STREYB)
-FS control board (FSCB)
<When FS-534 or FS-534SD is installed>
-Side stapler movement motor (M13)
-Stapler home position sensor (Rear) (PS23)
-FS control board (FSCB)

 Procedure

 When FS-533 is installed

  1. Check the connector between M107-STREYB CN123 for proper connection, and correct as necessary.
  2. Check the connector of M107 for proper drive coupling, and correct as necessary.
  3. Check the connector between PS110-FSCB CN110 for proper connection, and correct as necessary.
  4. PS110 I/O check, sensor check
    • Control signal: FSCB CN110
    • Location of electrical component: FS-533 8-D to E
  5. M107 operation check
    • Control signal: STREYB CN123-5 to 8
    • Location of electrical component: FS-533 5-L
  6. Replace M107. (Part# A2YUPPT400)
  7. Replace STREYB. (Part# A2YUPPG700)
  8. FSCB CP107 conduction check
  9. Replace FSCB. (Part# A2YUPPH901 for Model No. A2YU-WY1 or Part # A2YUPPXN00 for Model No. A2YU-WY2)

NOTICE

  • Link to the wiring diagram (FS-533)

 When FS-534 or FS-534SD is installed

  1. Check the connector between M13-relay CN3-FSCB J11 for proper connection, and correct as necessary.
  2. Check the connector of M13 for proper drive coupling and correct as necessary.
  3. Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary.
  4. PS23 I/O check, sensor check
    • Control signal: FSCB J11<B>-3 (ON)
    • Location of electrical component: FS-534 4-C
  5. M13 operation check
    • Control signal: FSCB J11<A>-1 to 4
    • Location of electrical component: FS-534 4-C to D
  6. Replace M13. (Part# A3EPPP9104)
  7. Replace FSCB. (Part# A3EPPPBE01)

NOTICE

  • Link to the wiring diagram (FS-534)

K.3.8.6 (Link to the Field Service Manual)

Table of Contents