Trouble typeC1109: Stapler motor drive malfunction (When FS-533, FS-534 or FS-534SD is installed)
RankB
Trouble detection condition<When FS-533 is installed>
-The stapler home sensor (PS110) is not turned ON (blocked) even after the set period of time has elapsed after the stapler motor turned ON.
<When FS-534 or FS-534SD is installed>
-The stapler home position sensor (Rear) (PS23) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the stapler motor (M14) turned ON.
-The stapler position sensor (Center) (PS24) is turned ON (blocked), when the stapler motor (M14) is running.
Trouble isolationStaple
Relevant electrical parts<When FS-533 is installed>
-Stapler home sensor (PS110)
-Stapler unit
-Stapler relay board (STREYB)
-FS control board (FSCB)
<When FS-534 or FS-534SD is installed>
-Stapler home position sensor (Rear) (PS23)
-Stapler unit
-Stapler position sensor (Center) (PS24)
-FS control board (FSCB)

 Procedure

 When FS-533 is installed

  1. Check the connector between the stapler unit-STREYB CN122 and CN123 for proper connection and correct as necessary.
  2. Check the connector of the stapler unit for proper drive coupling and correct as necessary.
  3. Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary.
  4. PS110 I/O check, sensor check
    • Control signal: FSCB CN110
    • Location of electrical component: FS-533 8-D to E
  5. Replace the stapler unit.(Part# A2YUPPK401)
  6. Replace STREYB. (Part# A2YUPPG700)
  7. Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

NOTICE

  • Link to the wiring diagram (FS-533)

 When FS-534 or FS-534SD is installed

  1. Check the connector between the stapler unit-relay CN4-FSCB J11 for proper connection and correct as necessary.
  2. Check the connector of the stapler unit for proper drive coupling and correct as necessary.
  3. Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary.
  4. Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary.
  5. PS23 I/O check, sensor check
    • Control signal: FSCB J11<B>-3 (ON)
    • Location of electrical component: FS-534 4-C
  6. PS24 I/O check, sensor check
    • Control signal: FSCB J11<B>-6 (ON)
    • Location of electrical component: FS-534 4 to 5-C
  7. Replace the stapler unit. (Part# A3EP560100)
  8. Replace FSCB.(Part# A3EPPPBE01)

NOTICE

  • Link to the wiring diagram (FS-534)

K.3.8.7 (Link to the Field Service Manual)