C1106 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeStapler movement motors malfunction
Trouble codeC1106
RankB
Detection timing<When FS-533 is installed>
• The stapler home sensor (PS110) is not unblocked after the laps of given time after it started operating from the home position.
• The stapler home sensor (PS110) is not unblocked after the laps of give time after the stapler movement motor (M107) turned ON when it returned to the home position.
<When FS-534 is installed>
• The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON.
• The stapler does not reach the specified position within the set period of time.
Trouble isolationStaple
Relevant electrical parts<When FS-533 is installed>
• Stapler movement motor (M107)
• Stapler home sensor (PS110)
• Stapler relay board (STREYB)
• FS control board (FSCB)
<When FS-534 is installed>
• Side stapler movement motor (M13)
• Stapler home position sensor (Rear) (PS23)
• FS control board (FSCB)

 (2)ProcedureWhen FS-533 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M107-STREYB CN123 for proper connection, and correct as necessary.
2Check the connector of M107 for proper drive coupling, and correct as necessary.
3Check the connector between PS110-FSCB CN110 for proper connection, and correct as necessary.
4PS110 I/O check, sensor checkFSCB CN110FS-533 8-D to E
5M107 operation checkSTREYB CN123-5 to 8FS-533 5-L
6Replace M107 (Part# A2YUPPT400 )
7Replace STREYB (Part# A2YUPPG700 )
8FSCB CP107 conduction check
9Replace FSCB (Part# A2YUPPH901 for Model No. A2YU-WY1 or Part # A2YUPPXN00 for Model No. A2YU-WY2)

When FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M13-relay CN3-FSCB J11 for proper connection, and correct as necessary.
2Check the connector of M13 for proper drive coupling, and correct as necessary.
3Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary.
4PS23 I/O check, sensor checkFSCB J11<B>-3 (ON)FS-534 4-C
5M13 operation checkFSCB J11<A>-1 to 4FS-534 4-C to D
6Replace M13 (Part# A3EPPP9104 )
7Replace FSCB (Part# A3EPPPBE01)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.6.6